  Datasheet File OCR Text:
 INIATURE FUSES MINIATURE FUSES
This product is not recommended for new designs. Please refer to Littelfuse No. 218.
5x20mm / No. 195
V, IEC 60127-2/III, 250 V, T
Time-Current Characteristic
Time Lag (T)
Specifications
Packaging
000: Bulk (1000 pcs.) 002: Bulk (20x10 pcs.) 043: With mounted holder - Tape/Reel (1250 pcs.) on request* *approvals pending for Pb-free fuse with holders Tube: End Caps: Optional Holders:
Standard
IEC 60127-2/III & DIN 41662 VDE SEMKO cULus Recognized BSI IMQ METI-PSE CCC Visual fault indication Direct solderable or plug-in versions Internationally approved Worldwide availability
Approvals
Materials
Dimensions (mm)
Features
Glass Nickel-plated brass Nickel-plated caps Tin-plated copper wires Temperature Operating Temperature -40 C to +85 C (consider de-rating) -40 C/+85 C / 21 days (IEC 60068-1,-2-1,-2-2,-2-78) +10 C to +60 C relative humidity 75 % yearly average, without dew, maximum value for 30 days-95 % 24 cycles at 15 min. each (EN 60068-6) 10 - 60 Hz at 0.75 mm amplitude 60 - 2000 Hz at 10 g acceleration 260 C, 3 s (Wave) 350 C, 1 s (Soldering iron) 260 C, 10 s (IEC 60068-2-20)
Climatic Category Stock Conditions
W ebLinks
Further info see:
www.wickmanngroup.com Optional Holders* www.wickmanngroup.com/download/ fuseology.pdf
Vibration Resistance
Further application info see fuseology: Solderability (mounted holders) Soldering Heat Resistance (mounted holders) Marking 4 x IN 10 x IN
, T, Current Rating, L, 250 V, Approvals
only 100 mA up to 16 A Limits for Pre-arcing Time
Rated Current
32 mA ... 100 mA 125 mA ... 10.00 A 12.50 A ... 16.00 A
1.5 x IN
>1h >1h > 30 min
2.1 x IN
< 2 min < 2 min < 10 min
2.75 x IN
200 ms ...10 s 600 ms ...10 s --
Unit Weight
40 ms ... 3 s 10 ms ... 300 ms 150 ms ... 3 s 20 ms ... 300 ms -20 ms ... 300 ms
1.1 g (approx.) 2.1 g (with leads)
32 mA 40 mA 50 mA 63 mA 80 mA 100 mA 125 mA 160 mA 200 mA 250 mA 315 mA 400 mA 500 mA 630 mA 800 mA 1.00 A 1.25 A 1.60 A 2.00 A 2.50 A 3.15 A 4.00 A 5.00 A 6.30 A 8.00 A 1 10.00 A 1 12.50 A 1 16.00 A 1
Permissible continuous operating current is 100 % at ambient temperature of 23 C (73.4 F). Rated Amp Voltage Breaking Voltage Drop Power Dissipation Melting Integral 1.5 x IN 10 x IN Current Code Rating Capacity 1.0 x IN max. (mV) max. (W) min. (A2s)
0032 0040 0050 0063 0080 0100 0125 0160 0200 0250 0315 0400 0500 0630 0800 1100 1125 1160 1200 1250 1315 1400 1500 1630 1800 2100 2125 2160 250 V 250 V 250 V 250 V 250 V 250 V 250 V 250 V 250 V 250 V 250 V 250 V 250 V 250 V 250 V 250 V 250 V 250 V 250 V 250 V 250 V 250 V 250 V 250 V 125 V / 250 V * 125 V / 250 V * 250 V 250 V 2500 1600 1500 1300 1100 1000 900 800 600 550 350 300 35A / 250 V AC 250 50-60 Hz 200 cos = 1.0 180 150 135 125 110 100 90 40 A/250 V AC/cos =1 80 50 A/250 V AC/cos =1 70 63 A/250 V AC/cos =1 70 63 A/250 V AC/cos =1 90 80 A/125 V AC/cos =1 63 A/250 V AC/cos =1 95 100 A/125V AC/cos =1 63 A/250 V AC/cos =1 120 63 A/250 V AC/cos =1 120 0.2 0.2 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.4 0.5 0.5 0.6 0.6 0.7 0.7 0.8 0.9 0.9 1.0 1.1 1.2 1.3 1.5 2.6 3.0 3.5 4.0 0.010 0.011 0.020 0.026 0.052 0.073 0.13 0.22 0.30 0.32 1.1 2.4 3.8 7.5 10 11 20 36 10 14 25 42 70 120 200 400 650 1000
METI-PSE
Approvals
SEMKO cURus IMQ VDE
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * * * * * * * * * * * * * * * * * * * * * * *
* * * * * * * * * * * * * * * * * * * * * * * *
* * * * * * * * * * * * * * * * * * * * * * * *
* * * * * * * *
CCC
BSI
* * * * * * * * * * * * * * * * * * * * * * * *
* * * *
1 Depending on the application and mounting, the fuse heating at max. ambient temperature in a closed fuseholder should be considered. * 125 V AC according to IEC 60127 (fuse is engraved with 125 V) / 250 V AC cURus approved.
Order Information
050912
Qty.
OrderNumber
Series 195
Amp Code
Packaging
Asia Tel: +852 26 14-1108 E-mail: sales@wickmann.com.hk
p=pending Specifications are subject to change without notice. China Tel: +86 21 6432 5146 E-mail: sales@wickmann.cn
WebSite Europe Tel: +49 2302 662-107 www.wickmanngroup.com E-mail: sales@wickmann.com
Americas Tel: +1 404 699-7820 E-mail: service@wickmannusa.com
INIATURE FUSES MINIATURE FUSES
5x20mm / No. 195
I-t Characteristics
(Min-Max Limit) IEC 60127-2/III (32 ... 100mA) IEC 60127-2/III (125mA ... 6.30A)
Time (sec.)
050912
WebSite Europe Tel: +49 2302 662-107 www.wickmanngroup.com E-mail: sales@wickmann.com
00 0,0 10 ,00 10 0 0 1,0 0 10 0 10 1 0.1 1 0.0 01 0.0
1
1.5
2
3
4
5
6
7 8 9 10
15
I Fault / I Rated
Contact WICKMANN for individual I-t curves
Americas Tel: +1 404 699-7820 E-mail: service@wickmannusa.com
Asia Tel: +852 26 14-1108 E-mail: sales@wickmann.com.hk
China Tel: +86 21 6432 5146 E-mail: sales@wickmann.cn


▲Up To Search▲   

 
Price & Availability of IEC60127-2III

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X